Page 1204 - MiSUMi 2025
P. 1204
Economy series Product Overview Product Overview Economy series
Photo Microsensors Photo Microsensors
· Advantage 3 : Widened welding spot spacing of substrate, fully automatic welding process, and not easy to
short circuit
Generic products on the market * MISUMI Economy series
Welding spot
spacing of
substrate is
The welding widened to
15 spot spacing 2.6mm, fixed 15
of substrate is
cable
Sensors / Noise Filters / Power Distribution Units / Contact Probes position, and Contact Probes Power Distribution Units / Sensors / Noise Filters /
only 2.1mm
not easy to
short circuit
Sensors · Advantage 4 : Full automatic inspection, with guaranteed product quality Sensors
Q Full automatic inspection equipment Q13 tests completed at one time
P.15-007 Initialization Settings Consumption Current Test (Normally Closed) P.15-007
Area Sensors / Safety Light Curtains / Safety Door Switches (Normally Closed) Load Current and Residual Voltage Test Safety Door Switches Safety Light Curtains / Area Sensors /
Pause Message
Consumption Current Test (Normally Open)
P.15-036 (Normally Open) Load Current and Residual Voltage Test P.15-036
Short Circuit Protection Test (Normally Closed) Short Circuit Protection Test (Normally Open)
Noise Filters Power Supply Reverse Connection Protection Test Tail Swing Test Filters Noise
Oscilloscope Frequency Test (Normally Open) Oscilloscope Frequency Test (Normally Closed)
P.15-050 Test End P.15-050
Power Distribution Units * Generic products on the market are similar products randomly purchased by MISUMI from the market. Units Power Distribution
P.15-052 P.15-052
QUsage Method
Contact Probes QMounting Method M3 Screw QConnector Type Probes Contact
· When fixing the body with · Plugging and unplugging steps of connector
P.15-054 Spring Washer Hook P.15-054
screws, use M3 screws,
φ6mm washers and Flat Washer 1 Insert the connector directly into Wiring Tab
control the tightening (O.D. φ6mm) the sensor until the connector tab is
torque below 0.5N·m locked in place by the sensor hook.
QWelding (Sensor)
· If welding directly on the terminal, please strictly follow the 5N or Less
conditions given below. 2 When pulling out, make sure that
Welding Sensor 1.5mm enough force is applied to release
Temperature 260℃ or Less the connector tab from the hook.
Welding 3S or Less Then pull it off.
Time Welding
Welding Refer to the Position Precautions: Make sure to hold the connector when
Position right diagram
plugging and unplugging it. In addition,
do not hold terminals or cables.
Otherwise, it will cause poor contact.
15-017