Page 1204 - MiSUMi 2025
P. 1204

Economy series         Product Overview                                                              Product Overview                                                       Economy series
                  Photo Microsensors                                                                                                                                                      Photo Microsensors



                 · Advantage 3 : Widened welding spot spacing of substrate, fully automatic welding process, and not easy to
                  short circuit
                          Generic products on the market *               MISUMI Economy series



                                                                                           Welding spot
                                                                                           spacing of
                                                                                           substrate is
                                               The welding                                 widened to
           15                                  spot spacing                                2.6mm, fixed                                                                                                           15
                                               of substrate is
                                                                                           cable
           Sensors / Noise Filters /  Power Distribution Units /   Contact Probes          position, and                                                                                                         Contact Probes  Power Distribution Units /   Sensors / Noise Filters /
                                               only 2.1mm
                                                                                           not easy to
                                                                                           short circuit




             Sensors   · Advantage 4 : Full automatic inspection, with guaranteed product quality                                                                                                                  Sensors

                    Q Full automatic inspection equipment     Q13 tests completed at one time
          P.15-007                                              Initialization Settings  Consumption Current Test (Normally Closed)                                                                              P.15-007
           Area Sensors /    Safety Light Curtains /   Safety Door Switches  (Normally Closed) Load Current and Residual Voltage Test                                                                            Safety Door Switches  Safety Light Curtains /   Area Sensors /

                                                                Pause Message
                                                                                     Consumption Current Test (Normally Open)
          P.15-036                                              (Normally Open) Load Current and Residual Voltage Test                                                                                           P.15-036
                                                                Short Circuit Protection Test (Normally Closed)   Short Circuit Protection Test (Normally Open)
            Noise   Filters                                     Power Supply Reverse Connection Protection Test  Tail Swing Test                                                                                  Filters  Noise
                                                                Oscilloscope Frequency Test (Normally Open)  Oscilloscope Frequency Test (Normally Closed)
          P.15-050                                              Test End                                                                                                                                         P.15-050
            Power Distribution   Units  * Generic products on the market are similar products randomly purchased by MISUMI from the market.                                                                       Units  Power Distribution




          P.15-052                                                                                                                                                                                               P.15-052
                 QUsage Method
            Contact   Probes  QMounting Method  M3 Screw      QConnector Type                                                                                                                                     Probes  Contact


                    · When fixing the body with               · Plugging and unplugging steps of connector
          P.15-054                             Spring Washer                                  Hook                                                                                                               P.15-054
                      screws, use M3 screws,
                      φ6mm washers and           Flat Washer   1 Insert the connector directly into   Wiring Tab
                      control the tightening     (O.D. φ6mm)   the sensor until the connector tab is
                      torque below 0.5N·m                      locked in place by the sensor hook.
                    QWelding (Sensor)
                    · If welding directly on the terminal, please strictly follow the       5N or Less
                     conditions given below.                  2 When pulling out, make sure that
                      Welding       Sensor     1.5mm           enough force is applied to release
                     Temperature  260℃ or Less                 the connector tab from the hook.
                      Welding   3S or Less                     Then pull it off.
                       Time                       Welding
                      Welding   Refer to the      Position    Precautions: Make sure to hold the connector when
                      Position  right diagram
                                                                     plugging and unplugging it. In addition,
                                                                     do not hold terminals or cables.
                                                                     Otherwise, it will cause poor contact.
          15-017
   1199   1200   1201   1202   1203   1204   1205   1206   1207   1208   1209