Economy series Product Overview Product Overview Economy series
Proximity Sensors Proximity Sensors
· Advantage 3: Bend resistant cable for M8/M12 specifications
Economy series New Q Bending Test Result
Specs
Proximity Sample name Service life Test result
Without
MISUMI
Sensors Economy series Bending 100,000 cycles breaking
Generic products
on the market * Bending 10,000 cycles Breaking
High accuracy detection
15 Use of oil resistant / bending resistant cable * Generic products on the market are similar products randomly purchased by MISUMI from the market. 15
* Test Method: Performed on a bending testing machine, ±90°, 60 cycles/minute, weight: 1kg
Sensors / Noise Filters / Power Distribution Units / Contact Probes DC 3-Wire Type NPN Output QUsage Method Contact Probes Power Distribution Units / Sensors / Noise Filters /
Input/Output Circuit Diagram
the magnetic flux
Color of Lead Wire
(Brown) + V ZD: Surge Absorbing Zener Q Shielded Proximity The shielded type has
concentrated in the
Diodes
Q Advantages of MISUMI Economy series Proximity Sensors
(Black) Output Load
Sensor
front of the sensor,
Sensors · Advantage 1: High accuracy detection Main Circuit (Blue) 0V Tr: NPN Output Transistor Output with the range of the Sensors
D: Diode for Power Supply
inductive magnetic
Internal Circuit External Connection Example Reverse Connection Protection field toward the front of
Detection Object the proximity sensor.
P.15-007 Generic products on the market * MISUMI Economy series DC 3-Wire Type PNP Output The unshielded coil P.15-007
Area Sensors / Safety Light Curtains / Safety Door Switches Input/Output Circuit Diagram Q Unshielded Proximity flux can increase the Safety Door Switches Safety Light Curtains / Area Sensors /
detection distance, but
it is easy to be affected
Color of Lead Wire
Diodes
because there is no
(Black) Output
P.15-036 Uneven Even winding (Brown) + V ZD: Surge Absorbing Zener Sensor Output by surrounding metals P.15-036
winding of
Tr: PNP Output Transistor
coils of coil Main Circuit (Blue) 0V Load D: Diode for Power Supply Detection protection sheath.
Attention is required
Stable
Noise Filters Inconsistent detection Internal Circuit External Connection Example Reverse Connection Protection Object during installation. Filters Noise
detection
distance distance
P.15-050 QPrecautions P.15-050
Power Distribution Units * Generic products on the market are similar products randomly purchased by MISUMI from the market. · Sensor Attenuation Coefficient Units Power Distribution
within the range of the following formula.
P.15-052 * The test data are obtained through testing by MISUMI, which are for reference only. Tested Material Attenuation Coefficient The number of connected sensors (N) should be P.15-052
1.00
Fe360 Steel
iL+(N-1)×i ≤ Upper limit value of control output of
Chromium Nickel Alloy
0.90
proximity sensor
· Advantage 2: Oil resistant cable for M8/M12 cable specifications
Contact Probes Stainless Steel 0.85 VS-N×V ≤ R Operating voltage of load Probes Contact
Cable Sheath Oil Resistance Test Result Nickel 0.70 N: Number of connectable sensors
VR: Output residual voltage of proximity sensor
P.15-054 Brass 0.50 AND Load VS: Power voltage P.15-054
I: Current consumption of proximity sensor
Specification MISUMI Economy series Reference Copper 0.40 (Series iL: Load current
Test Item Unit
Value Measured Value Standard Aluminum 0.40 Connection) Note: Connection AND can supply power to the
14 DC Wire Type 3 proximity sensor of (A) through the action of the
Tensile Strength MPa Above 12.0 18.4 X t=1mm proximity sensor of (B), and the proximity sensor
Tensile JIS K 6723 12 d of (A) sometimes generates an error pulse
Test 10 Iron (about 1ms) when the power is turned on.
Elongation % Above 300 431 8 (SPCC) Therefore, please pay attention to the loads
Tensile Strength Detection Distance X (mm) 6 Stainless Steel that require quick response, which may cause
Tensile Residual Rate % —— 99.8 Brass false operation.
Test After JIS K 6723 4 At least 3 sensors with current output can be
Oil Elongation % —— 81.5 70°C×500Hr 2 Aluminum Copper OR Load connected as OR.
Residual Rate (Parallel Whether more than 4 sensors can be connected
0 5 10 15 20 25 30 35 40 Connection) depends on different models.
The oil resistance test value of MISUMI Economy series product is much higher than the specification value. The length of one side of detected object: d (mm)
15-008